Opulent Knee System
🦿 ArthroplastyREF: MRL-ORTHO-003✓ Brochure Verified

Opulent Knee System

· Knee Implants

Total Knee Replacement System with TiNbN Coating
MaterialCobalt-Chromium Alloy
WhatsApp Quote
Full Technical Matrix
Full Technical Matrix

Opulent Knee System

Technical Blueprint SpecificationClinical Value
Coating Thickness
3-6 μm
Roughness
≤ 0.05 μm
Adhesive strength (according to Rockwell indentation test)
HF 1-2
Coating hardness
ca. 2,400 HV (0.1 N)
Friction against UHMWPE
0.04-0.07
Liquid contact angle
Reduction of the liquid contact angle by 20%, result: improved wettability of the surface compared to uncoated CoCrMo surfaces

Coating

TiNbN (Titanium Niobium Nitride) ceramic surface coating

Wear resistance

Very high wear resistance towards bone cement

Wear

Reduction of UHMWPE wear

Sensitization test according to 10993-1

No sensitization from TiNbN

Irritation test according to ISO 10993-1

No irritant reactions from TiNbN coating

Implantation according to DIN EN ISO 10993-6

No product-related tissue reactions

Allergy potential

Release of ions was reduced to the detection limit

Cytotoxicity

Not cytotoxic

Genotoxicity

Not genotoxic

Primary Material

Cobalt-Chromium Alloy

CDSCO Validated Data
Anatomical Sizing Wizard

Anatomical Wizard

Clinical Sizing Precision

MM
Frequently Asked Questions

Total Knee Replacement System with TiNbN Coating

The Opulent Knee System features a TiNbN ceramic coating with a roughness of ≤ 0.05 μm and a friction coefficient of 0.04-0.07 against UHMWPE, which contributes to very high wear resistance. This reduces UHMWPE wear and improves the articulation precision of the implant, leading to optimized kinematic function and potentially longer implant lifespan.

The TiNbN coating demonstrates excellent biocompatibility, evidenced by sensitization and irritation tests according to ISO 10993-1 standards, which show no sensitization or irritant reactions. Furthermore, implantation tests per DIN EN ISO 10993-6 indicate no product-related tissue reactions, with ion release reduced to the detection limit, confirming its biocompatible nature.

The TiNbN coating reduces the liquid contact angle by 20%, leading to improved wettability of the surface, this results in better bone cement adhesion. Furthermore, the coating's adhesive strength (HF 1-2 per Rockwell indentation test) and high wear resistance ensures stability during and after implantation procedures.

This product is manufactured by Meril Life Sciences and is distributed by Agile Healthcare across all districts of Telangana.

Yes, all Meril Life Sciences products distributed by Agile Healthcare, including the Opulent Knee System, strictly adhere to CDSCO guidelines and ISO 13485:2016 quality standards.

The Opulent Knee System is constructed using Cobalt-Chromium Alloy, ensuring high biocompatibility and durability.