BioMime Aura Sirolimus Eluting Coronary Stent System
❤️ CardiovascularREF: Multiple SKU codes based on diameter and length combinations (BIA22508, BIA23008, etc.)✓ Brochure Verified

BioMime Aura Sirolimus Eluting Coronary Stent System

BioMime · Drug Eluting Stents

Sirolimus Eluting Coronary Stent System, consistent clinical safety & efficacy in more than 1650 patients up to 5 years.
MaterialCobalt Chromium (L605)
WhatsApp Quote
Full Technical Matrix
Full Technical Matrix

BioMime Aura Sirolimus Eluting Coronary Stent System

Technical Blueprint SpecificationClinical Value
STENT Material
Cobalt Chromium (L605)
Strut Thickness
65µm (0.065mm or 0.026")
Stent Diameter (mm)
2.00, 2.25, 2.50, 2.,75, 3.00, 3.50, 4.00, 4.50
Stent Length (mm)
8, 13, 16, 19, 24, 29, 32, 37, 40, 44, 48
Mean Recoil
≤4.0%
Mean Foreshortening
≤1.0%
Equivalent Drug Dose
1.25 µg/mm²
Nominal Pressure
9 atm (Refer IFU)
Rated Burst Pressure
Rated Burst Pressure: 14/16 atm* (*RBP 14 atm for all diameter with length >40mm. (Refer IFU for more details))
Balloon Overhang
≤ 0.5 mm
Shaft Outer Diameter
Proximal: 2.13 F, Distal: 2.7 F (Refer IFU for more details)
Usable Catheter Length
142 cm (Refer IFU for more details)
Guide Catheter Compatibility
5F (Min. I. D. 0.056" / 1.42 mm)
Max. Guidewire
0.014" (0.36)
Stent Diameter 2.00 mm
0.83mm/0.033"
Stent Diameter 2.25 mm
0.85mm/0.033"
Stent Diameter 2.50 mm
0.91mm/0.036"
Stent Diameter 2.75 mm
0.98mm/0.039"
Stent Diameter 3.00 mm
0.99mm/0.039"
Stent Diameter 3.50 mm
1.06mm/0.042"
Stent Diameter 4.00 mm
1.16mm/0.046"
Stent Diameter 4.50 mm
1.19mm/0.047"
Tip Entry Profile
0.016"
Elongated distal tip
7.00 ± 0.5 mm

Drug

Sirolimus

Polymer

Biodegradable & Biocompatible (PLLA + PLGA)

Delivery System

Rapid Exchange

Radiopaque Markers

Two Platinum / Iridium Markers

Crossing Profile

Crossing Profile

Primary Material

Cobalt Chromium (L605)

CDSCO Validated Data
Anatomical Sizing Wizard

Anatomical Wizard

Clinical Sizing Precision

MM
Frequently Asked Questions

Sirolimus eluting coronary stent system with 65μm strut thickness, biodegradable polymer coating, morphology mediated expansion, and advanced delivery system

This product is manufactured by Meril Life Sciences Pvt. Ltd. and is distributed by Agile Healthcare across all districts of Telangana.

Yes, all Meril Life Sciences products distributed by Agile Healthcare, including the BioMime Aura Sirolimus Eluting Coronary Stent System, strictly adhere to CDSCO guidelines and ISO 13485:2016 quality standards.

The BioMime Aura Sirolimus Eluting Coronary Stent System is constructed using Cobalt Chromium (L605), ensuring high biocompatibility and durability.